AXEO 3 Patient Monitor

$1,111.00

In stock

SKU: AXEO3 Category:




Features and Benefits

  • Large 12.1 LCD TFT high definition flat panel display with touch screen.
  • 8 Channel selectable wave forms
  • Programmable NIBP cycles (2 min – 4 hours)
  • Programmable audible / visual alarms
  • Simultaneous display of all parameters
  • Real time wave form history for on screen review
  • Trend information on all parameters
  • Alarm triggered printout
  • Adult to neonatal usage
  • AC/DC operation

Functions



Standard

  • 3 or 5 Lead ECG
  • NIBP
  • SpO2
  • Impedance Respiration
  • Temperature
  • ST Segment and Arrhythmia Analysis
  • Priority Alarms
  • Tabular Trending / Graphical Trending
  • Touch Screen
  • Drug Calculations
  • OXY CRG
  • Patient ID Input
  • Ethernet / RS-232
  • 2 Temperatures
  • Large Fonts

Optional

  • Thermal Strip Chart Recorder
  • Mobile Cart with Basket
  • Two Invasive Pressure
  • EtCO2

Materials Included

  • AXEO 3 unit
  • (1) Adult Blood Pressure Cuff with Hose
  • (1) SpO2 Adult Finger Probe
  • (1) 3/5 lead ECG Cables with leads
  • (1) Hospital Grade Power Cord
  • (1) Skin Temperature Probe
  • (1) User Manual

Technical Specifications

  • Application
    • Neonatal
    • Pediatric
    • Adult
  • Dimensions: 345 Ч 336 Ч 165 mm (13.5′ x 13.25′ x 6.5”)
  • Weight: 15 lbs
  • Performance Specifications
    • Display: 12.1 inch Color TFT Touchscreen
    • Trace: 4, 6 or 8 Waveforms
    • Waveforms: ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBP1, IBP2, EtCO2
    • Indicators:
      • Alarm Indicator
      • Power Indicators
      • QRS beep and alarm sound
    • Trend time: From 30 mins to 72 hours
    • Recorder:
      • Built-in, thermal array, 3 channels
      • Record width: 48mm
      • Recorder paper: 50mm
      • Record speed: 25mm/s, 50mm/s
  • ECG
    • Input: 3 or 5-lead ECG cable, AAMI standard
    • Lead Selections: I, II, III, aVR, aVF, aVL, V
    • Gain Selections: Ч0.25 Ч0.5 Ч1.0 Ч2.0
    • Frequency Characteristics: 0.5-40Hz ±3dB Monitor, 0.05-130Hz Diag.
    • ECG Waveforms: 7 channels
    • Sweep Speeds: 12.5, 25 and 50mm/s
    • HR Display Range: 0-300bpm
    • Accuracy: ±1bpm or ±1%, whichever is greater
    • Alarm limit range:
      • Upper limit: 80-400bpm
      • Lower limit: 20-150bpm
  • Respiration
    • Measurement Method: RA-LL impedance (Lead II)
    • Range: 0-120rpm
    • Accuracy: +3rpm
    • Alarm Upper-lower Limit:
      • Upper limit: 6-120rpm
      • Lower limit: 3-120rpm
    • Sweep Speed: 6.25, 12.5, and 25mm/s
  • NIBP
    • Measurement Technology: Automatic Oscillometric Measurement
    • Cuff Inflation: &lt, 30s-0-300mmHg standard adult cuff
    • Measurement Period: Average &lt, 40s
    • Operating Modes: Manual, Auto, STAT
    • Measurement Interval in AUTO Mode: 2 minutes to 4 hours
    • Pulse Rate Range: 30 bpm – 250 bpm
    • Measuring Range:
      • Adult/Pediatric Mode
        • SYS 40-250mmHg
        • DIA 15-200mmHg
      • Neonatal Mode
        • SYS 40-135mmHg
        • DIA 15-100mmHg
    • Resolution: 1mmHg
    • Pressure Accuracy:
      • Maximum Mean Error: 5mmHg
      • Maximum Standard Deviation: 8mmHg
    • Overpressure Protection:
      • Adult Mode: 297mmHg
      • Neonatal Mode: 147mmHg
    • Alarm Limit:
      • SYS 30-240mmHg
      • DIA 15-180mmHg
  • Temperature
    • Range: 0-50 C
    • Accuracy:
      • + 0.2° @ 25.0-34.9 C
      • + 0.1° @ 35.0-39.9 C
      • + 0.2° @ 40.0-44.9 C
      • + 0.3° @ 45.0-50.0 C
    • Display Resolution: 0.1 C
    • Units: Selectable, C or F
    • Alarm Upper-lower Limit: Upper limit 0-50, Lower limit 0-50 C
    • Channels: 2 channels plus
    • Temperature Alarm Limit: 10-50 C
  • SpO2
    • ASpO2: Anti-motion SpO2 SpO2%
    • Range: 0-100%, with proportional pitch beep
    • SpO2 Accuracy:
      • + 2% 70-100%,non-motion
      • + 3% 70-100%, motion
    • Pulse Rate Range: 0-250 bpm
    • Pulse Rate Accuracy: ±2 bpm (non-motion), ±3 bpm (motion)
    • Alarm Upper-Lower Limit:
      • Upper limit 50-100%
      • Lower limit 50-100%
    • SpO2 Probe
      • Red LED wavelength 660nm±5nm
      • Infrared LED wavelength 940nm±10nm
  • IBP (Option)
    • Measurement Range: -10 to 300mmHg
    • Channels: 2 channels
    • Pressure transducer: Sensitivity, 5µV/V/mmHg
    • Impedance range: 300-3000
    • Transducer sites: ART, PA,CVP, RAP, LAP, ICP
    • Resolution: 1mmHg
    • Accuracy: ±1mmHg or ±2%, whichever is greater
    • Alarm Range: -10 to 300mmHg
  • EtCO2 (Option)
    • Mode of Sampling: Sidestream or Mainstream
    • Principle of Operation: Nondispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
    • CO2 measurement Range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
    • CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
    • CO2 Resolution: 0.1mmHg (0-69mmHg), 0.25mmHg (70- 150mmHg)
    • CO2 Accuracy:
      • 0&#65374,40 ± 2mmHg
      • 41&#65374,70mmHg ±5% of reading
      • 71&#65374,100mmHg ±8% of reading
      • 101&#65374,150mmHg ±10% of reading
      • &gt, 80 breath per minute ±12% of reading
    • Sampling Rate: 100 Hz
    • Respiration Rate: 2-150bpm
    • Respiration Rate Accuracy: ±1 breath
    • Response Time: &lt,3 seconds, includes transport and rise time
    • Inspired CO2 Measurement Range: 3-50mmHg
  • Power
    • Source: External AC power and internal battery
    • AC Power: 100-240VAC, 50/60Hz, 150VA
    • Battery: Built-in and rechargeable
    • Charge Time: 16 hours
    • Operating Time: 4 hours
    • Fuse: F5.0A250V
  • Environmental Specifications
    • Temperature: Operating: 0-40°C Storage: -20-60°C
    • Humidity Range: Operating: 15-95% Storage: 10-95%
  • Battery
    • Type: PS-1290 12V-9AH
    • Operating Time On Battery: 4 hours Operating Time After Low
    • Battery Alarm: 30 minutes
  • Recorder (Option)
    • Record Width: 48mm
    • Paper Speeds: 25mm/s, 50mm/s
    • Traces: 3
  • LCD Specifications
    • Display Type: TFT color LCD
    • Size (diagonal): 31cm (12.1”)
    • Active Area: 246.0 H Ч184.5 V Pixel Format 800 H Ч 600 V (1 pixel=R + G + B dots)
    • Pixel Pitch (W x H): 0.3075 x 0.3075mm
    • Number of Colors (Resolution): 262,144 colors (6 bits/color)
    • Display Mode: Normally white Surface Treatment: Anti-glare and hard-coating 3H
  • Touchscreen Specifications
    • Type: Four-Wire Analog Resistive Touch Panel
    • Input Modes: Stylus Pen or Finger
    • Active Area: 245.00±0.20Ч183.00±0.20mm
    • Total Thickness: 2.25±0.20mm
    • Transparency: 78 ± 3% (Measured by BYK-Gardner)
    • Haze: Antiglare Finish 10 ± 3%
    • Knock Test: 1,000,000 times

Warranty Information

  • 2-Year Warranty