AXEO 3 Patient Monitor
$1,111.00
Features and Benefits
- Large 12.1 LCD TFT high definition flat panel display with touch screen.
- 8 Channel selectable wave forms
- Programmable NIBP cycles (2 min – 4 hours)
- Programmable audible / visual alarms
- Simultaneous display of all parameters
- Real time wave form history for on screen review
- Trend information on all parameters
- Alarm triggered printout
- Adult to neonatal usage
- AC/DC operation
Functions
Standard
- 3 or 5 Lead ECG
- NIBP
- SpO2
- Impedance Respiration
- Temperature
- ST Segment and Arrhythmia Analysis
- Priority Alarms
- Tabular Trending / Graphical Trending
- Touch Screen
- Drug Calculations
- OXY CRG
- Patient ID Input
- Ethernet / RS-232
- 2 Temperatures
- Large Fonts
Optional
- Thermal Strip Chart Recorder
- Mobile Cart with Basket
- Two Invasive Pressure
- EtCO2
Materials Included
- AXEO 3 unit
- (1) Adult Blood Pressure Cuff with Hose
- (1) SpO2 Adult Finger Probe
- (1) 3/5 lead ECG Cables with leads
- (1) Hospital Grade Power Cord
- (1) Skin Temperature Probe
- (1) User Manual
Technical Specifications
- Application
- Neonatal
- Pediatric
- Adult
- Dimensions: 345 Ч 336 Ч 165 mm (13.5′ x 13.25′ x 6.5”)
- Weight: 15 lbs
- Performance Specifications
- Display: 12.1 inch Color TFT Touchscreen
- Trace: 4, 6 or 8 Waveforms
- Waveforms: ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBP1, IBP2, EtCO2
- Indicators:
- Alarm Indicator
- Power Indicators
- QRS beep and alarm sound
- Trend time: From 30 mins to 72 hours
- Recorder:
- Built-in, thermal array, 3 channels
- Record width: 48mm
- Recorder paper: 50mm
- Record speed: 25mm/s, 50mm/s
- ECG
- Input: 3 or 5-lead ECG cable, AAMI standard
- Lead Selections: I, II, III, aVR, aVF, aVL, V
- Gain Selections: Ч0.25 Ч0.5 Ч1.0 Ч2.0
- Frequency Characteristics: 0.5-40Hz ±3dB Monitor, 0.05-130Hz Diag.
- ECG Waveforms: 7 channels
- Sweep Speeds: 12.5, 25 and 50mm/s
- HR Display Range: 0-300bpm
- Accuracy: ±1bpm or ±1%, whichever is greater
- Alarm limit range:
- Upper limit: 80-400bpm
- Lower limit: 20-150bpm
- Respiration
- Measurement Method: RA-LL impedance (Lead II)
- Range: 0-120rpm
- Accuracy: +3rpm
- Alarm Upper-lower Limit:
- Upper limit: 6-120rpm
- Lower limit: 3-120rpm
- Sweep Speed: 6.25, 12.5, and 25mm/s
- NIBP
- Measurement Technology: Automatic Oscillometric Measurement
- Cuff Inflation: <, 30s-0-300mmHg standard adult cuff
- Measurement Period: Average <, 40s
- Operating Modes: Manual, Auto, STAT
- Measurement Interval in AUTO Mode: 2 minutes to 4 hours
- Pulse Rate Range: 30 bpm – 250 bpm
- Measuring Range:
- Adult/Pediatric Mode
- SYS 40-250mmHg
- DIA 15-200mmHg
- Neonatal Mode
- SYS 40-135mmHg
- DIA 15-100mmHg
- Adult/Pediatric Mode
- Resolution: 1mmHg
- Pressure Accuracy:
- Maximum Mean Error: 5mmHg
- Maximum Standard Deviation: 8mmHg
- Overpressure Protection:
- Adult Mode: 297mmHg
- Neonatal Mode: 147mmHg
- Alarm Limit:
- SYS 30-240mmHg
- DIA 15-180mmHg
- Temperature
- Range: 0-50 C
- Accuracy:
- + 0.2° @ 25.0-34.9 C
- + 0.1° @ 35.0-39.9 C
- + 0.2° @ 40.0-44.9 C
- + 0.3° @ 45.0-50.0 C
- Display Resolution: 0.1 C
- Units: Selectable, C or F
- Alarm Upper-lower Limit: Upper limit 0-50, Lower limit 0-50 C
- Channels: 2 channels plus
- Temperature Alarm Limit: 10-50 C
- SpO2
- ASpO2: Anti-motion SpO2 SpO2%
- Range: 0-100%, with proportional pitch beep
- SpO2 Accuracy:
- + 2% 70-100%,non-motion
- + 3% 70-100%, motion
- Pulse Rate Range: 0-250 bpm
- Pulse Rate Accuracy: ±2 bpm (non-motion), ±3 bpm (motion)
- Alarm Upper-Lower Limit:
- Upper limit 50-100%
- Lower limit 50-100%
- SpO2 Probe
- Red LED wavelength 660nm±5nm
- Infrared LED wavelength 940nm±10nm
- IBP (Option)
- Measurement Range: -10 to 300mmHg
- Channels: 2 channels
- Pressure transducer: Sensitivity, 5µV/V/mmHg
- Impedance range: 300-3000
- Transducer sites: ART, PA,CVP, RAP, LAP, ICP
- Resolution: 1mmHg
- Accuracy: ±1mmHg or ±2%, whichever is greater
- Alarm Range: -10 to 300mmHg
- EtCO2 (Option)
- Mode of Sampling: Sidestream or Mainstream
- Principle of Operation: Nondispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts
- CO2 measurement Range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
- CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated)
- CO2 Resolution: 0.1mmHg (0-69mmHg), 0.25mmHg (70- 150mmHg)
- CO2 Accuracy:
- 0~,40 ± 2mmHg
- 41~,70mmHg ±5% of reading
- 71~,100mmHg ±8% of reading
- 101~,150mmHg ±10% of reading
- >, 80 breath per minute ±12% of reading
- Sampling Rate: 100 Hz
- Respiration Rate: 2-150bpm
- Respiration Rate Accuracy: ±1 breath
- Response Time: <,3 seconds, includes transport and rise time
- Inspired CO2 Measurement Range: 3-50mmHg
- Power
- Source: External AC power and internal battery
- AC Power: 100-240VAC, 50/60Hz, 150VA
- Battery: Built-in and rechargeable
- Charge Time: 16 hours
- Operating Time: 4 hours
- Fuse: F5.0A250V
- Environmental Specifications
- Temperature: Operating: 0-40°C Storage: -20-60°C
- Humidity Range: Operating: 15-95% Storage: 10-95%
- Battery
- Type: PS-1290 12V-9AH
- Operating Time On Battery: 4 hours Operating Time After Low
- Battery Alarm: 30 minutes
- Recorder (Option)
- Record Width: 48mm
- Paper Speeds: 25mm/s, 50mm/s
- Traces: 3
- LCD Specifications
- Display Type: TFT color LCD
- Size (diagonal): 31cm (12.1”)
- Active Area: 246.0 H Ч184.5 V Pixel Format 800 H Ч 600 V (1 pixel=R + G + B dots)
- Pixel Pitch (W x H): 0.3075 x 0.3075mm
- Number of Colors (Resolution): 262,144 colors (6 bits/color)
- Display Mode: Normally white Surface Treatment: Anti-glare and hard-coating 3H
- Touchscreen Specifications
- Type: Four-Wire Analog Resistive Touch Panel
- Input Modes: Stylus Pen or Finger
- Active Area: 245.00±0.20Ч183.00±0.20mm
- Total Thickness: 2.25±0.20mm
- Transparency: 78 ± 3% (Measured by BYK-Gardner)
- Haze: Antiglare Finish 10 ± 3%
- Knock Test: 1,000,000 times
Warranty Information
- 2-Year Warranty